Coalescing cartridges for liquid removal from gaseous media

SoloToV® Filtering material SoloToV®: wound layers of controlled density impregnated glass fibre material
Filtering material SoloToV®-B: pleated layers of controlled density impregnated glass fibre material
Application: for separation of condensates from wet gases combined with the removal of fine solid particles. Also available in pleated version (SoloToV®-B), to increase filtering surface where space issues occur (f.e. retrofitting)
Temperature resistance: continuous operating temperature 70°C; maximum surge 120°C (pH 7).
For medium temperature cartridges type -MT: continuous operating temperature: 120°C (pH 7).
For medium high temperature cartridges type -MHT: continuous operating temperature: 180°C (pH 7).
For (ultra) high temperature cartridges type -UHT: continuous operating temperature: >240°C (pH 7).
DuoToV® Filtering material: 
integrated pre-filter section: multilayer pleated assembly
coalescer section: wound layers of controlled density impregnated glass fibre material
Application: excellent for cases where both condensate and particle separation from moist gases are required. An integrated pre-filter effectively separates solid particles, thus considerably increasing the cartridge lifetime
Temperature resistance: for standard cartridges continuous operating temperature 70°C; maximum surge 120°C (pH 7).
For medium temperature cartridges type -MT: continuous operating temperature: 120°C (pH 7).
For medium high temperature cartridges type -MHT: continuous operating temperature: 170°C (pH 7).
For ultra high temperature cartridges type -UHT: continuous operating temperature: 240°C (pH 7).
MicroToV® Filtering material:
integrated pre-filter section: multilayer pleated assembly
coalescer section: wound layers of controlled density impregnated glass fibre material with additional micro-separation phase
Application: to remove fine oil mist, condensate and solids from moist gases. A special microlayer for conditioning oil mist in the gas stream is integrated in this cartridge. Like the DuoToV®, an integrated pre-filter effectively separates solid particles.
Temperature resistance: for standard cartridges continuous operating temperature 70°C; maximum surge 120°C (pH 7).
For medium temperature cartridges type -MT: continuous operating temperature: 120°C (pH 7).
For medium high temperature cartridges type -MHT: continuous operating temperature: 170°C (pH 7).
For ultra high temperature cartridges type -UHT: continuous operating temperature: 240°C (pH 7).